Electrical Specifications

Capacitance, pF/m (ft) 80 (24.4)
Impedance, ohms 50±1
Velocity, Present 83
Peak power Rating, kW 19
RF Peak Voltage, KV 1.13
Insulation Resistance, M Ωkm >5000
Cut-off Frequency. (GHz) 12.5
Insulation Voltage, KV 2.5
Inner Conductor DC Resistance.Ω/km 2.85
Outer Conductor DC Resistance, Ω/km 3.50
Jacket Spark, KV 5.0
Shielding Effectiveness, db >120
VSWR (Return Loss)
0.005 – 3 GHz ≤1.15(≥23 dB)
0.8 – 1.0 GHz ≤1.10(≥26 dB)
1.7 – 2.0 GHz ≤1.10(≥26dB)
2.0 – 2.4 GHz ≤1.10(≥26dB)

Mechanical and Environmental Specifications

Minimum bending Radius
Single  Bend. mm(in) 40(0.6)
Repeated Bends. mm(in) 95(4)
Number of Bends 15
Mobile Apply. mm(in) 250(10)
Bending Moment. N m(lb-ft) 1.9(1.4)
Tensile Strength, kg(lb) 53(19)
Storage Temperature, 0C(0F) -55to+85(-67to+185)
Inner Conductor DC Resistance.Ω/km 2.85
Outer Conductor DC Resistance, Ω/km 3.50
Jacket Spark, KV 5.0
Shielding Effectiveness, db >120
VSWR (Return Loss)
0.005 – 3 GHz ≤1.15(≥23 dB)
0.8 – 1.0 GHz ≤1.10(≥26 dB)
1.7 – 2.0 GHz ≤1.10(≥26dB)
2.0 – 2.4 GHz ≤1.10(≥26dB)

Construction Specifications Material

Inner Conductor Copper Clad Aluminum wire or copper
Dielectric Physical Foam Polyethylene
Outer Conductor Jacket Helical Copper Tube Black PE or Low Smoke Halogen Free Fire-Retardant

Physical Dimensions

Inner Conductor Diameter , mm (in) 3.55 (0.14)
Dielectric Diameter , mm (in) 8.7 (0.34)
Outer Conductor Diameter , mm (in) 12.00 (0.47)
Diameter Over Jacket, mm (in) 13.4 (0.53)

Standard Conditions

For Attenuation : VSWR 1.0, Cable temperature 20 0C (68 0F)
For average power : VSWR1.0, ambient temperature’e 40 0C (104 0F)
Inner conductor temperature 100 0C (212 0F), No Solar Loading.

Connector

Type Number Description
SNM-1/2SF N Male ½” Super Flexible
SNF-1/2SF DIN Male ½” Super Flexible
SDINF-1/2SF DIN Female ½” Super Flexible